3-phase ac filters / dc filters fmad rail www.schurter.com/pg8 0 emc products 1-stage filter for 3-phase systems with neutral conductor, din rail mounting description - 3 phase line filter with standard attenuation - din rail mounting - easy and time saving handling approvals - vde certificate number: 40030736 - ul file number: e72928 applications - especially designed for electric switch and control cabinets - qualified for use in equipment according iec/en 60950 references weblinks general product informatio n , approval s , roh s , china-roh s , e-stor e , schurter-stock-chec k , distributor-stock-chec k technical data rated current 3 - 20 a @ ta 40 c rated voltage 275 - 480 vac, 50/60 hz approval for 6 - 20 a / 275 - 480 vac overload current 1.5 x ir leakage current industrial < 1 ma (440 v / 50 hz) dielectric strength for 480 vac 2.25 kvdc between l-l 1.7 kvdc between l-n 3 kvdc between l-pe test voltage (2 sec) number of filter stages 1 weight 0.4 kg material: housing metal sealing compound ul 94v-0 mounting din rail mounting terminal bolts and nuts m4, quick connect ter - minal for pe operating temperature [c] -25 c to 100 c climatic category 25/100/21 acc. to iec 60068-1 degree of protection ip 20 acc. to iec 60529 protection class suitable for appliances with protection class 1 acc. to iec 61140 mtbf > 200'000 h acc. to mil-hb-217 f
3-phase ac filters / dc filters fmad rail www.schurter.com/pg8 0 emc products dimensions (6.5) max. 61 1) (75) max. 102 en 60715 35x7.5 2) 11.5 11.5 11.5 13 max. 61 27 16 max. 48 l 2 l 3 l 1 l 2 ? l 3 ? n n? l 1 ? 3) 4) 1) line 2) load 3) tightening torque 0.6-0.8 nm, screw 4mm2 4) quick connect terminal 6.3x0.8mm technical data to the filter components rated current [a] rated voltage [vac] l [mh] c [nf] c [nf] 10 275 - 480 0.4 100 4.7 20 275 - 480 0.15 100 22 3 275 - 480 1 100 4.7 6 275 - 480 0.5 100 4.7 diagrams 1) 2) 1) line 2) load
3 3-phase ac filters / dc filters fmad rail www.schurter.com/pg8 0 emc products attenuation loss . . . . . 0.1/100 ? differential mode ........... 100/0.1 ? differential mode - - - - differential mode _____ common mode industrial version 3 a 6 a 10 a 20 a variants rated current [a] tripped power dissi - leakage current [ma] ) contact resistance [m ? ] weight [g] screw clamps [mm ] ) order number 10 3.2 0.5 8 395 4 FMAD-MRYB-1010 20 5.8 2 3.6 420 4 fmad-mryb-2010 3 1.4 0.5 38 385 4 fmad-mryb-0310 6 1.7 0.5 11.5 385 4 fmad-mryb-0610 1) worst case leakage current acc. to iec60950 - annex g4 (situation with two interrupted lines). nominal leakage current acc. to iec60950 - 5.2.5. can be found in section technical data. 2) maximum conductor cross section (wire gauge) to be used; a comparative table for awg and mm2 values can be found in the general product information www.schurter.com/emc_info packaging unit 5 pcs the specifications, descriptions and illustrations indicated in this document are based on current information. all content is subject to modifications and amendments.
|